Hot Air Cooling Project
Author:sehenstar Source:本站 Pubtime:2017-11-22 11:15:44 Click:547
Customer Request
1. Working Condition: Hot air cooling
- We have some work coming up the need some pillow plates for heat echangers
- This is a 8 pillow plates bundle for heat exchange
- Water at 20 degr C in the plates
- Hot turbulent air, 400 - 450 m3/hr @ 800 - 950 degr C
- The plates will have channels
- Clean water flow rate for each plate is 6 to 10 L/min
- Operating pressure maximum 7 Bar
- Delta-T 80 degr C
2. Material: Ss304
Sehenstar Proposal
1. Type of Heat Exchanger: Flue gas heat exchanger2. Drawing:
- PrevSol:Natural Gas Generator Flue Gas Cooling
- NextSol:Dried Clay Cooling
Contact Us
(86)0512-69572850