Energy Saving Solutions———More Energy Conserved, More The Planet Life Is Reserved.
 [field:title/]
Cooler For Light Soda Ash
Author:sehenstar  Source:本站  Pubtime:2017-11-27 11:54:42  Click:630

Customer Request

1. Working Condition: Cooler For Light Soda Ash (LSA)

    - System capacity: 20 MTH of LSA 

    - Cooling range: from 200 C to 100 C 

    - Bulk density 0,5 ÷ 0,55 t/m3

    - Particle size distribution

< 0,1 mm –         39,2 %

0,1 ÷ 0,4mm –   56,7 %

0,4 ÷ 0,5mm –     1,4 %

0,5 ÷ 0,8mm –     1,4 %

0,8 ÷ 1,7mm –     0,7 %

1,6 ÷ 2,5mm –     0,3 %

> 2,5 mm –           0,3 %

    - Max. particle size according to size distribution

    - Specific heat –  1,042 J/g °C

    - Angle of Repose – 29 ÷ 37

    - Cooling medium – water

    - Cooling medium inlet – temperature 22 °C

    - Cooling medium inlet flow rate – as per deliverer

    - Additional information if special requirements needed: optimal design of the cooler

2. Material: Ss304


Sehenstar Proposal

1. Type of Heat Exchanger: Bulk solid heat exchanger

2. Drawing:


Contact Us
(86)0512-69572850
Add:Xi'an Jiao Tong University Science Park,Xiangcheng District,Suzhou,CN