Customer Request
1. Working Condition: Cooler For Light Soda Ash (LSA)
- System capacity: 20 MTH of LSA
- Cooling range: from 200 C to 100 C
- Bulk density 0,5 ÷ 0,55 t/m3
- Particle size distribution
< 0,1 mm – 39,2 %
0,1 ÷ 0,4mm – 56,7 %
0,4 ÷ 0,5mm – 1,4 %
0,5 ÷ 0,8mm – 1,4 %
0,8 ÷ 1,7mm – 0,7 %
1,6 ÷ 2,5mm – 0,3 %
> 2,5 mm – 0,3 %
- Max. particle size according to size distribution
- Specific heat – 1,042 J/g °C
- Angle of Repose – 29 ÷ 37
- Cooling medium – water
- Cooling medium inlet – temperature 22 °C
- Cooling medium inlet flow rate – as per deliverer
- Additional information if special requirements needed: optimal design of the cooler
2. Material: Ss304
Sehenstar Proposal
1. Type of Heat Exchanger: Bulk solid heat exchanger
2. Drawing:
- PrevSol:Water Chiller For Milk Processing Plant
- NextSol:Flue Gas Cooling From Diesel Burner