Customer Request
1. Working Condition: Lime Kiln Production Flue Gas Cooling
- A lime kiln production line with capacity of 200,000 ton per year
- Flue gas from the production line is 260~280℃
- To be cooled down to 150~180℃
- Flow rate 90,000-100,000Nm3
- Cooling medium: water
- From 80℃ to 136℃
- Outlet pressure 0.25MPa
- Flue gas content as follows:
|
Content |
Percentage |
3.1 |
CO2 |
24% |
3.2 |
N2 |
65% |
3.3 |
O2 |
6% |
3.4 |
H2O |
5% |
2. Material: Ss304
Sehenstar Proposal
1. Type of Heat Exchanger: Flue gas heat exchanger2. Drawing:
- PrevSol:Biodiesel Boiler Flue Gas Cooling
- NextSol:Natural Gas Generator Flue Gas Cooling