Customer Request
1. Working Condition: Cement Cooling
Site conditions
- Altitude 200 m
- Ambient temperature -5ºC / 25ºC
- Relative humidity, average 85% , min 79%
- Seismic zone Basic seismic acceleration 0,3 g
- Low voltage 380V
- Control 220V
- Instrumentation 4 – 20 mA
- Frequency 50Hz
Data from inquiry
- Cement flow 80 t/h
- Inlet max temperature 95ºC
- Outlet desired temperature 60ºC
Material characteristics
- Material Cement
- Specific surfac 5000 blaine
- Density (transport) 0,95 t/m3
- Angle of response 0-20º
- Material humidity <0,5%
Water characteristics
- Range for inlet water temperature* (15ºC-30ºC)
- Range for outlet water temperature (25ºC-40ºC)
- PH 7
- Chlorides 19 mg/l
- Soluble solids 313 mg/l
- Hardness Unknow
*According site conditions average water inlet temperature 15ºC
Please clarify clearly water specifications for cement functioning.
Location of cement cooler in the plant
- Outdoor
2. Material: Ss304
Sehenstar Proposal
1. Type of Heat Exchanger: Bulk solid heat exchanger2. Drawing:
- PrevSol:Cooling Of Output Waste Water From Fish Factory
- NextSol:Sugar Soybean Dregs Mixture Cooling